Linden Hof

Services

Technical review for the decision in front of you

We work on solar PV, battery storage and hybrid systems with generators, from a single factory roof to utility scale. Each engagement has a fixed scope, a fixed fee and a delivery date, agreed before we start.

For lenders, funds and arrangers

Pre-commitment technical review

A fixed-fee technical check on a single loan, where a full independent engineer is out of proportion to the deal, or a fast, independent first read of a larger project before credit approval.

Request a review

What we check

  • PPA, design, yield report and financial model against each other
  • Sizing against the borrower's real load, and the savings the repayment depends on
  • P50 and P90 basis, data source and uncertainty budget
  • Battery fade and augmentation against the debt tenor
  • O&M budget, mid-life inverter replacement and reserves
  • Grid connection status, export limits and curtailment
  • Land or lease term against the loan and PPA term

Scope, clearly stated

  • Every report lists what was reviewed, at which revision, and what was not
  • Where a formal independent engineer's report with reliance is required, we work alongside the appointed firm as its local associate

You receive a findings register ranked critical, major and minor, and a one-page summary written for a credit paper.

For businesses buying solar

Quote and design review

You have one or more EPC proposals. We tell you whether the system fits your load and your process, whether the price is fair, and what to change in the contract before you sign.

Free: 12 questions to ask before you sign a solar quote

Get a quote reviewed

What we check

  • Sizing against 12 months of interval load data, not the monthly bill
  • Yield, losses and derating at your site temperature
  • Inverter capacity against your largest motor starts and generator steps
  • Battery energy at the meter, cycles, fade and warranty terms
  • Protection, earthing and power quality with variable-speed drives
  • Price against landed equipment cost and duties

Contract terms we look for

  • A performance guarantee that is measurable and has a remedy
  • Warranties that run from commissioning, not shipment
  • A locked bill of materials: no substitution without approval
  • Acceptance tests at site conditions before final payment

You receive a review memo with a clear recommendation: sign, renegotiate (with the clauses to change), or re-tender.

For developers and owners

Owner's-side technical support

From design basis to handover, we write down what you are buying and check that the contractor delivers it.

Discuss your project

What we deliver

  • Design basis: sizing, dispatch and the assumptions behind them
  • Employer's requirements for FIDIC Yellow and Silver Book contracts
  • Technical bid evaluation and clarification rounds
  • Guarantees on performance ratio, availability and battery round-trip efficiency, including cooling loads
  • Liquidated damages sized to the shortfall they cover

Through construction

  • Design submittal review
  • Factory and site acceptance test procedures
  • Commissioning and capacity test witness
  • Registered engineers engaged where formal sign-off is required

You receive contract-ready technical schedules and a test regime that proves the plant meets them.

For engineering and advisory firms

Local associate, East Africa

For international owner's engineers and independent engineers with mandates in Kenya and the region.

Check availability

What we cover

  • Site visits, photo and condition reports
  • Grid, licensing and regulatory input: EPRA, KPLC, net metering and open access in Kenya
  • First-pass data-room review to your checklist
  • Contractor and supplier meetings in Nairobi

How it works

  • Day rate or fixed fee per task
  • Your mandate, your report, your reliance; we work to your quality system

You receive a reliable local team without the cost of flying one in.

For investors and research teams

Expert briefings

Short, paid calls on solar and storage in East Africa: technology choices, costs, Kenya's C&I procurement routes, and what makes small deals financeable.

Book a briefing

Typical topics

  • Captive solar, net metering, private wire and open access in Kenya
  • Battery sizing and warranties for C&I sites
  • Hybrid systems for process plants and mines

Booked through

  • Expert networks, or directly with us

Standard reviews

Fixed scope, fixed fee, fixed date

ReviewScopeTurnaround
Per-loan technical checkOne C&I solar or storage loan5 working days
Quote and design reviewUp to three EPC proposals for one site5 working days
Data-room red-flag reviewOne utility-scale project15 working days
Local associateSite visits and local input on your mandateAs scheduled

Turnaround starts when we have the documents. Fees are agreed in writing before we start, after a short call and a look at the document list.

How an engagement runs

From first call to findings

  1. 1

    Call and document list

    30 minutes, no charge. You tell us the decision and the deadline.

  2. 2

    Fixed proposal

    Scope, fee and delivery date in writing within two working days.

  3. 3

    Review the source files

    Native simulation files, drawings, models and contracts, not summaries.

  4. 4

    Findings register

    Ranked by effect on cash, each with its number, cost and fix.

  5. 5

    Walk-through

    A session with your team or credit committee on what to do next.

Tools and partners

How the work is done

WorkHow we do it
Energy yield and lossesPVsyst: native file review and independent energy yield assessment
PV, battery and generator mixHOMER Pro models, built or reviewed
Hourly dispatch and battery state of charge8,760-hour models, built and checked
Sizing, motor starting, ride-throughHand calculations, shown in every report
Load flow, short circuit, transients, protectionSpecialist partners run DIgSILENT and PSCAD; we scope the study, check its inputs and review its results
Civil, structural and geotechnicalSpecialist partners

Questions clients ask

Before you get in touch

Getting started

What do you need from us to start?

For a project review: the PPA or offtake terms, the design and single-line diagram, the yield report with its native simulation files, the financial model, the EPC and supply contracts, and land documents. Send whatever exists; we tell you what is missing.

For a quote review: your last 12 months of electricity bills or meter data, generator fuel records if you run one, and the proposals you have received.

Confidentiality

Do you sign NDAs?

Yes. We sign your NDA before you send any documents. Project and client names never appear in our marketing without written permission.

Due diligence

How does technical due diligence improve a solar project?

It finds contradictions between the PPA, the design, the yield report and the financial model before money is committed, when they are cheapest to fix. Typical findings: installed capacity below the contract, an optimistic P90, missing CapEx such as storage, and gaps in warranties or land terms.

Lenders

Can you act as lender's technical adviser?

Where your process requires a formal independent engineer's report with reliance, we work alongside the appointed firm as its local associate. For smaller loans, our fixed-fee technical check gives your credit team what it needs at a cost in proportion to the deal. We also act as local associate to an appointed independent engineer.

Owners

Do you provide owner's engineering in Nairobi?

We support owners with design review, specifications, employer's requirements and acceptance tests. Where a project needs certification or formal sign-off, we work with registered engineers.

Scope

Which technologies and countries do you cover?

Solar PV, battery storage and hybrid systems with generators. We are based in Nairobi and work across Africa: document reviews are done remotely, and site visits are arranged per project. We review technical documents in English and French.

Fees

How are fees set?

A fixed fee for an agreed scope, quoted after a short call and a look at the document list. The standard reviews above cover most requests.

Reviewing a solar or storage project?

Tell us what you are deciding and when. We reply within two working days.